    ABB Bailey IMCOM03 Net 90 Controller Module

    Bailey INFI 90 · Enhanced Controller

    ABB Bailey IMCOM03 Mixed I/O Controller Module

    A controller module that combines process-control execution with four analog inputs, three digital inputs, two analog outputs and four digital outputs. IMCOM03 is the documented direct replacement for the Network 90 NCOM03 and uses NICS01 or NTCS02 for field termination.

    TypeMixed I/O controller
    SystemINFI 90 / Network 90
    TerminationNICS01 or NTCS02
    BrandElsag Bailey / ABB
    Talk to a spare-parts specialistMiya Zheng
    Email for quotationsales@amikon.cn
    WhatsApp+86 180 2077 6792
    05 / Product Introduction

    Control execution and mixed field I/O on one module

    IMCOM03 reads process signals, executes the configured control strategy and drives analog and digital outputs. It is especially relevant where a single legacy controller card carries both logic and direct field connections.

    01

    Input acquisition

    Accepts four analog inputs and three digital inputs through the selected termination assembly.

    02

    Control strategy

    Executes configured function blocks to monitor and control the process.

    03

    Output actuation

    Provides two analog outputs and four isolated open-collector digital outputs.

    Field inputs4 AI + 3 DI
    ControllerIMCOM03 function blocks
    Field outputs2 AO + 4 DO
    06 / Technical Specifications

    Power requirements and confirmed mixed-I/O capability

    ModelIMCOM03
    Product typeEnhanced mixed-I/O controller module
    System familyBailey INFI 90; direct replacement for Network 90 NCOM03
    Analog inputs4 channels; 1 to 5 VDC or 4 to 20 mA
    Digital inputs3 channels; termination drawings cover 24 VDC and 125 VDC arrangements
    Analog outputs2 channels; 1 to 5 VDC or 4 to 20 mA
    Digital outputs4 isolated open-collector channels, 24 VDC
    Digital-output maximum on current150 mA
    Digital-output off current10 µA
    Digital-output maximum on voltage1.5 V at 150 mA
    +5 VDC load0.75 A / 3.75 W maximum
    +15 VDC load89 mA / 1.335 W maximum
    −15 VDC load74 mA / 1.11 W maximum
    +24 VDC load50 mA / 1.2 W maximum
    Termination-module optionNICS01
    Termination-unit optionNTCS02
    NICS01 cable optionsNKTM01 or NKTU02
    NTCS02 cableNKTU01
    Front status indicationGreen: enabled and communicating; red: bus error; off: no power or not enabled
    02 / Termination & Wiring

    Select the field interface already used by the installation

    The controller supports two documented termination paths. Match the installed termination product and cable rather than selecting the controller card in isolation.

    01

    NICS01 termination module

    Handles the four analog inputs, two analog outputs, three digital inputs and four digital outputs; connects with NKTM01 or NKTU02.

    02

    NTCS02 termination unit

    Provides the alternative field termination arrangement and connects through NKTU01.

    03

    Signal-range match

    Analog points must agree with the configured 1–5 VDC or 4–20 mA range, and digital wiring must match the installed termination design.

    03 / Configuration & Commissioning

    Function blocks define how the controller uses each signal

    The hardware does not determine the control strategy by itself. The saved module configuration is required to restore the same input processing, logic and output behavior after replacement.

    1Back up the configurationSave the complete function-block strategy and tuning values before removing the module.
    2Label every field channelKeep AI, DI, AO and DO wiring identities aligned with the termination points.
    3Verify signal typesConfirm voltage/current ranges and the digital input supply used by the installed design.
    4Commission outputs safelyProve analog and digital outputs under controlled process conditions before returning automatic control.
    04 / Diagnostics & Maintenance

    The front LED gives the first controller-health clue

    Use the LED together with module status and termination checks to distinguish a bus problem, disabled module, power loss or field-side fault.

    Fault isolation sequence

    • Green indicates the controller is enabled and communicating.
    • Red identifies a bus error that should be investigated before field wiring.
    • An unlit LED points to loss of power or a module that is not enabled.
    • For a single bad point, check the matching termination channel and field circuit.
    05 / Compatibility & Replacement

    A direct replacement for Network 90 NCOM03

    The original manufacturer instruction identifies IMCOM03 as the direct replacement for NCOM03. The installed termination, cable, signal ranges and saved control configuration must still be carried across correctly.

    01

    Legacy controller

    NCOM03 in a Network 90 installation

    02

    Documented replacement

    IMCOM03 enhanced controller module

    03

    Installation checks

    Termination type, cable, field voltage, configuration and output commissioning

    07 / Applications & Fault Scenarios

    Operational problems that point toward IMCOM03

    01

    Several mixed I/O points fail together

    Loss of multiple inputs and outputs can indicate controller, bus, power or termination-cable trouble.

    02

    Controller shows a red status LED

    The module reports a bus error and the rack communication path needs investigation.

    03

    NCOM03 lifecycle replacement

    A site is preparing the documented direct replacement while retaining its existing control strategy and field wiring.

    08 / Official Documentation

    IMCOM03 manufacturer documents

    ManufacturerDocumentNumber / VersionOfficial link
    Elsag Bailey / ABBController Modules IMCOM03 and IMCOM04 — Product InstructionI-E96-207A View document
    ABBSymphony Plus Lifecycle UpdatesABB User Group presentation View document
    09 / Supply & RFQ

    Inspection, packing and quotation support

    Amikon Service

    InspectionPart identity and agreed test scope
    Export packingAnti-static and impact-protective
    DOA supportPrompt review with photos and evidence
    Warranty & returnsTerms confirmed on the quotation
    10 / FAQ

    IMCOM03 questions from buyers and maintenance teams

    What is ABB Bailey IMCOM03 used for?

    It executes a configured control strategy while directly handling four analog inputs, three digital inputs, two analog outputs and four digital outputs.

    Which termination hardware works with ABB Bailey IMCOM03?

    The original instruction documents NICS01 with NKTM01 or NKTU02 cables, or NTCS02 with an NKTU01 cable.

    What analog signal ranges does ABB Bailey IMCOM03 support?

    The four inputs and two outputs support 1–5 VDC or 4–20 mA signal ranges.

    What does a red LED mean on ABB Bailey IMCOM03?

    A solid red front status LED indicates a bus error. A solid green LED indicates enabled communication.

    Does ABB Bailey IMCOM03 replace NCOM03?

    Yes. The manufacturer instruction identifies IMCOM03 as the direct replacement for the Network 90 NCOM03 controller.

    What must be preserved before replacing ABB Bailey IMCOM03?

    Save the function-block configuration and tuning values, identify the termination and cable, label all field channels and document each signal range.

    11 / Multi-brand Spare Parts Also Requested

    Independent procurement references

    These models are separate sourcing references, not substitutes for IMCOM03. Compatibility and stock must be confirmed independently.

    210N2272972-01268-6A-IP20311637312863-A01319828-A01332985-C013G3MX2-A4007-ZV13IF722.93IF761.93IF766.93IF771.93IF772.93IF779.9

    No interchangeability, migration or replacement relationship is implied by this list.

    IMCOM03 · ABB / Bailey industrial automation spare · Contact Miya Zheng for availability and quotation support.
    Quality ABB Bailey IMCOM03 Net 90 Controller Module for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: AMIKON LIMITED
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Find Similar Products By Category: