Sign In | Join Free | My burrillandco.com
Home > ABB PLC >

ABB INICT12 Cnet-to-Computer Transfer Module

AMIKON LIMITED
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap ABB INICT12 Cnet-to-Computer Transfer Module from wholesalers
     
    Buy cheap ABB INICT12 Cnet-to-Computer Transfer Module from wholesalers
    • Buy cheap ABB INICT12 Cnet-to-Computer Transfer Module from wholesalers
    • Buy cheap ABB INICT12 Cnet-to-Computer Transfer Module from wholesalers
    • Buy cheap ABB INICT12 Cnet-to-Computer Transfer Module from wholesalers
    • Buy cheap ABB INICT12 Cnet-to-Computer Transfer Module from wholesalers

    ABB INICT12 Cnet-to-Computer Transfer Module

    Ask Lasest Price
    Model Number : INICT12
    Delivery Time : 5-8 working days
    Brand Name : ABB
    Supply Ability : Subject to availability
    • Product Details
    • Company Profile

    ABB INICT12 Cnet-to-Computer Transfer Module

    ABB Harmony Rack Communications · INICI12

    ABB INICT12 Cnet-to-Computer Transfer Module

    The transfer processor in an INICI12 computer interface, built to move Cnet data to a host through two RS-232-C channels. It maintains a 10,000-point definition database and uses a command-driven receive, execute and reply cycle for host transactions.

    TypeComputer transfer module
    InterfaceCnet-to-host
    AssemblyINICI12
    BrandABB Bailey
    Talk to a spare-parts specialistMiya Zheng
    Email for quotationsales@amikon.cn
    WhatsApp+86 180 2077 6792
    04 / Product Introduction

    The host-facing processor in an INICI12 interface

    INICT12 is not a standalone Ethernet gateway. It works with INNIS01 on the Cnet side and NTMP01 on the serial host side, so a correct spare decision starts with the complete INICI12 assembly.

    01

    Collects Cnet data

    Receives system information through the companion INNIS01 network interface.

    02

    Maintains a point database

    Supports up to 10,000 configured point definitions for host access.

    03

    Serves host commands

    Receives a command, executes the requested operation and returns the reply over RS-232-C.

    Control networkCnet + INNIS01
    Transfer processorINICT12
    Host sideNTMP01 + RS-232-C
    05 / Technical Specifications

    Confirmed interface capacity, memory and serial data

    ModelINICT12
    Product typeCnet-to-computer transfer module
    Interface assemblyINICI12
    Read-only memory512 KB ROM
    Random-access memory512 KB RAM
    Nonvolatile memory128 KB NVRAM
    Power requirement+5 VDC at 2 A
    Power consumption10 W
    Serial interfacesTwo RS-232-C ports
    Maximum serial rate19.2 kbaud
    Point-definition capacity10,000 points
    Host transaction modelCommand-driven receive, execute and reply
    Termination hardwareNTMP01 multi-function processor termination unit
    DTE / DCE selectionSelected by NTMP01 jumper configuration
    Network-interface companionINNIS01
    MountingOne module-mounting-unit slot
    Operating temperature0 to 70°C (32 to 158°F)
    Relative humidity5% to 90% up to 55°C; 5% to 40% above 55°C, noncondensing
    AltitudeSea level to 3 km (1.86 mi)
    ApprovalsFM Class I, Division 2, Groups A–D; CSA ordinary locations
    02 / Host Interface

    A disciplined command cycle for supervisory access

    INICT12 supports host functions without replacing the control system's controller execution. The host requests information or an allowed action, and the module returns a response.

    01

    Data acquisition

    Makes configured Cnet point data available to the host computer.

    02

    Monitoring and control

    Supports documented supervisory monitoring and command functions.

    03

    System services

    Handles security, time synchronization, status and module-configuration transactions used by the interface.

    03 / Serial Wiring & Commissioning

    NTMP01 jumpers determine the DTE or DCE connection

    A correct RS-232-C cable can still fail if the termination-unit jumper role does not match the host equipment. Treat the NTMP01 setup as part of the interface.

    1Identify the host port roleRecord which serial channel is connected to the computer and how the second port is used.
    2Verify DTE/DCE jumpersMatch NTMP01 to the host or modem connection before changing cables.
    3Match the data rateConfirm the selected rate at both ends, up to the documented 19.2 kbaud maximum.
    4Retain the point configurationBack up the point definition and interface settings before hardware work.
    04 / Compatibility Boundary

    Conductor VMS uses a different documented interface path

    ABB's rack communication data states that a Conductor VMS workstation uses IIMCP02 with IIMLM01 rather than INICI03 or INICI12. This distinction matters when the host platform is being identified for a spare request.

    Use INICT12 when

    The installed assembly is INICI12 and the host path is the documented two-port serial computer interface.

    06 / Applications & Fault Scenarios

    Common INICT12 maintenance and purchasing cases

    01

    Host data stops updating

    The computer loses fresh Cnet values while controller-side process execution continues.

    02

    Serial commands time out

    DTE/DCE jumpers, cable, data rate, host settings or transfer-module status interrupt the receive/reply cycle.

    03

    Point database recovery

    A replacement is being prepared together with the saved 10,000-point interface configuration.

    07 / Official Documentation

    INICT12 manufacturer documents

    ManufacturerDocumentNumber / VersionOfficial link
    ABBHarmony Rack Communications — Data SheetWBPEEUD250001C1, Rev. C1 View document
    ABBHarmony Rack Communications — OverviewWBPEEUS250002C1, Rev. C1 View document
    08 / Supply & RFQ

    Inspection, packing and quotation support

    Amikon Service

    InspectionPart identity and agreed test scope
    Export packingAnti-static and impact-protective
    DOA supportPrompt review with photos and evidence
    Warranty & returnsTerms confirmed on the quotation
    09 / FAQ

    INICT12 questions from buyers and maintenance teams

    What is ABB INICT12 used for?

    It is the host-transfer processor in an INICI12 interface, moving configured Cnet data and commands between the control network and a serial computer.

    How many points can ABB INICT12 define?

    The documented interface capacity is 10,000 point definitions.

    Which termination unit is used with ABB INICT12?

    NTMP01 terminates the two RS-232-C channels and provides the jumper selection for DTE or DCE operation.

    Which network module works with ABB INICT12?

    INNIS01 supplies the Cnet-side network interface for the INICI12 assembly.

    Is ABB INICT12 the documented interface for a Conductor VMS workstation?

    No. ABB identifies IIMCP02 with IIMLM01 for Conductor VMS rather than an INICI03 or INICI12 interface.

    What should be checked when ABB INICT12 host communication fails?

    Check INNIS01 status, NTMP01 DTE/DCE jumpers, serial cable, configured data rate, host settings and the saved point database.

    10 / Multi-brand Spare Parts Also Requested

    Independent procurement references

    These models are separate sourcing references, not substitutes for INICT12. Compatibility and stock must be confirmed independently.

    210N2272972-01268-6A-IP20311637312863-A01319828-A01332985-C013G3MX2-A4007-ZV13IF722.93IF761.93IF766.93IF771.93IF772.93IF779.9

    No interchangeability, migration or replacement relationship is implied by this list.

    INICT12 · ABB / Bailey industrial automation spare · Contact Miya Zheng for availability and quotation support.
    Quality ABB INICT12 Cnet-to-Computer Transfer Module for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: AMIKON LIMITED
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Find Similar Products By Category: