Sign In | Join Free | My burrillandco.com
Home > ABB PLC >

ABB Bailey IMAMM03 Analog Master Module

AMIKON LIMITED
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap ABB Bailey IMAMM03 Analog Master Module from wholesalers
     
    Buy cheap ABB Bailey IMAMM03 Analog Master Module from wholesalers
    • Buy cheap ABB Bailey IMAMM03 Analog Master Module from wholesalers
    • Buy cheap ABB Bailey IMAMM03 Analog Master Module from wholesalers
    • Buy cheap ABB Bailey IMAMM03 Analog Master Module from wholesalers

    ABB Bailey IMAMM03 Analog Master Module

    Ask Lasest Price
    Model Number : IMAMM03
    Delivery Time : 2-3 work days
    Payment Terms : T/T
    Supply Ability : In stock
    Brand Name : ABB
    Price : USD 66 / Piece
    • Product Details
    • Company Profile

    ABB Bailey IMAMM03 Analog Master Module

    AMIKON · ABB AUTOMATION SPARE · TECHNICAL PRODUCT NOTE

    IMAMM03

    The IMAMM03 Analog Master Module is the processing and communication master for an INFI 90 analog input subsystem. With IMASM01, IMASM02, IMASM03 or IMASM04 slave modules, it accepts as many as 64 high-level, thermocouple, millivolt or RTD signals for control, trending, alarm and exception-reporting functions.

    Type
    Analog master module
    System
    Bailey INFI 90 / ABB Harmony rack I/O
    Focus
    Analog subsystem processing, slave-group management and redundancy
    Brand
    ABB / Bailey
    Contact: Miya Zheng · sales@amikon.cn · WhatsApp: +86 180 2077 6792
    Email WhatsApp
    01

    Product Introduction

    The IMAMM03 Analog Master Module is the processing and communication master for an INFI 90 analog input subsystem. With IMASM01, IMASM02, IMASM03 or IMASM04 slave modules, it accepts as many as 64 high-level, thermocouple, millivolt or RTD signals for control, trending, alarm and exception-reporting functions.

    02

    Technical Specifications

    01Input capacityUp to 64 analog inputs in eight groups of eight
    02Supported slavesUp to four IMASM01, or up to eight IMASM02 / IMASM03 / IMASM04 modules
    03Input span-10 to +10 VDC
    04Common-mode voltage±5 VDC maximum
    05Input impedanceGreater than 10 MΩ
    06A/D conversion16 bit; 15-bit guaranteed linearity
    07Master accuracy at 25°C±0.01% of span typical; ±0.025% maximum, excluding slave module
    08Normal-mode rejection-80 dB at 60 Hz
    09RAM24 kB
    10ROM36 kB
    11Battery-backed RAM6 kB
    12+5 VDC power825 mA maximum; 4.13 W maximum
    13+15 VDC power150 mA maximum; 1.88 W maximum
    14-15 VDC power40 mA maximum; 0.45 W maximum
    15MountingOne slot in a standard INFI 90 Module Mounting Unit
    16Operating temperature0 to 70°C (32 to 158°F)
    17Humidity0 to 95% RH to 55°C; 0 to 45% RH at 70°C, noncondensing
    18AltitudeSea level to 3 km (1.86 mi)
    19AtmosphereNoncorrosive
    20CertificationCSA certified for ordinary, nonhazardous locations
    03

    Compatibility & Replacement

    01

    Original-System Compatibility

    Works with IMASM01, IMASM02, IMASM03 and IMASM04 analog slave modules. P1 carries module-bus power and communication, P2 connects the slave expander bus, and P3 supports redundant-master or termination arrangements. NTAM01 and NIAM02 hardware is used in documented redundancy, indicator-station and thermocouple arrangements.

    02

    Historical Replacement

    ABB evolution material states that the AMM/ASM family can be evolved to the IMASI23 Universal Analog Input Module. This is a system migration, not a drop-in swap: an MFP or later controller and minor configuration changes are required.

    04

    Applications & Fault Scenarios

    • Mixed high-level, thermocouple, millivolt and RTD acquisition in process control systems.
    • Signal linearization, cold-junction compensation, engineering-unit conversion, trending, alarms and exception reporting.
    • Maintenance searches commonly follow a failed primary/backup handover, missing slave group, bad point quality, calibration drift, memory diagnostic or configuration mismatch.
    • Failure of the master can remove multiple analog groups at once; without working redundancy, this can stop control sequences or extend an outage.
    05

    Redundancy

    • A backup master can take control using current process data so processing and control continue without interruption.
    • Documented redundancy uses the P3 connection and the specified NTAM01/NIAM02 arrangement; duplicate the primary module's configuration and cable topology exactly.
    • Up to four NDIS01 indicator stations, serving up to 12 points, are supported in the documented architecture.
    06

    Configuration & Installation

    • S2 selects run/diagnostic functions and the module address; S1 is the reset switch.
    • P1 is the module-bus interface, P2 is the slave expander bus, and P3 is used for redundancy or termination, depending on the installation.
    • After replacement, load the required configuration into the new master before returning the loop set to service.
    07

    Diagnostics & Maintenance

    • Five front-panel LEDs report operating mode and normal/error status; built-in tests cover memory, timing, communication and redundancy functions.
    • At six-month intervals or during a shutdown, calibrate as required, tighten and clean power/ground connections, and remove dust with static-safe vacuum equipment.
    • The manufacturer procedure replaces a faulty module rather than repairing components in the field. Preserve all switch, jumper, cable and slot information before exchange.
    08

    Official Manufacturer Sources

    01
    Bailey Controls Company · I-E96-205A

    Analog Master Module and Analog Slave Modules Product Instruction

    Original manufacturer source for capacity, memory, power, redundancy, installation, diagnostics and maintenance.

    Original document ID
    02
    ABB · 3BUS095666

    Symphony Plus Overview – AMM / ASM Evolution

    Evolution to IMASI23, MFP-or-later controller requirement and configuration-change guidance.

    03
    ABB · 3BUS095548

    Services for Symphony Harmony / INFI 90 Process Control Systems

    AMM/ASM lifecycle status and ABB migration-service guidance.

    09

    Amikon Service

    Test & Packing

    Pre-shipment check, antistatic protection and reinforced packing.

    DOA & Returns

    Prompt review under the written order terms with fault evidence.

    Warranty

    Covers confirmed supply defects during the agreed period.

    Sales Support

    Part-number, revision and system checks before dispatch.

    10

    Request for Quotation

    RFQ checklist

    Send the Part Number, Quantity, Destination, Required Date and Machine/System Model. A clear nameplate photo helps confirm the request.

    11

    Multi-brand Spare Parts Also Requested

    12

    FAQ

    01How should IMAMM03 be installed after a failure?
    Record the slot, S2 address, cable positions, slave arrangement and redundancy wiring before removal. Fit the replacement with the same settings, then load and verify the required configuration before restoring the analog groups.
    02Can IMAMM03 be replaced by IMASI23 without other changes?
    No. ABB describes this as an engineered evolution path requiring an MFP or later controller and minor configuration changes. Termination, channel mapping and outage planning must be reviewed first.
    03What must be configured on IMAMM03?
    Set the module address and operating mode, define the attached slave groups and input functions, and make sure the backup master carries the matching database when redundancy is used.
    04What maintenance and ESD controls apply to IMAMM03?
    Use a grounded wrist strap and antistatic packaging. At the scheduled interval, check calibration, power and ground connections, clean the cabinet with static-safe equipment and investigate LED or diagnostic results before replacing hardware.
    05What delivery and warranty support is available for IMAMM03?
    Each unit is function-checked where suitable test facilities are available and packed in an antistatic bag with protective cushioning. DOA, return and exchange requests are handled under the written order terms after evidence and technical evaluation. Warranty covers confirmed supply defects during the agreed period, excluding misuse, incorrect installation, ESD damage, improper storage and unauthorized repair.
    06What information is needed for an IMAMM03 RFQ?
    Please provide the Part Number, Quantity, Destination, Required Date and Machine/System Model. Also include the slave-module mix, controller type and a clear nameplate photo when available.

    Technical statements are limited to verified ABB/Bailey manufacturer documentation. Installation must follow the plant safety procedure and the documentation for the installed system revision.