Sign In | Join Free | My burrillandco.com
Home > ABB PLC >

ABB INIIT13 INFINET Communication Module

AMIKON LIMITED
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap ABB INIIT13 INFINET Communication Module from wholesalers
     
    Buy cheap ABB INIIT13 INFINET Communication Module from wholesalers
    • Buy cheap ABB INIIT13 INFINET Communication Module from wholesalers
    • Buy cheap ABB INIIT13 INFINET Communication Module from wholesalers
    • Buy cheap ABB INIIT13 INFINET Communication Module from wholesalers

    ABB INIIT13 INFINET Communication Module

    Ask Lasest Price
    Delivery Time : 5-8 working days
    Model Number : INIIT13
    Brand Name : ABB
    Supply Ability : Subject to availability
    • Product Details
    • Company Profile

    ABB INIIT13 INFINET Communication Module

    ABB Bailey INFI 90 · Local Network Transfer

    ABB INIIT13 INFI-to-INFI-Net Local Transfer Module

    A local transfer module used to facilitate communication between two local INFI-NET / Cnet networks. The installed INIIT13 remains a legacy spare-parts identity, while ABB's current Symphony Plus platform documents SPIIT13 and the SPIIL02-L local-transfer kit for the same architectural role.

    TypeLocal transfer module
    SystemINFI 90 / Harmony
    FocusTwo local networks
    BrandABB Bailey
    Talk to a spare-parts specialistMiya Zheng
    Email for quotationsales@amikon.cn
    WhatsApp+86 180 2077 6792
    04 / Product Introduction

    A local bridge between two control networks

    INIIT13 belongs in a paired local-transfer architecture, not a remote modem link. For sourcing, capture the full faceplate identity and the surrounding network-interface hardware at both connected networks.

    01

    Local network transfer

    Facilitates communication between two local control networks within the plant architecture.

    02

    Legacy installed identity

    INIIT13 remains the exact model to match when maintaining an existing INFI 90 or Harmony rack node.

    03

    Current platform context

    ABB's Symphony Plus catalog documents SPIIT13 and the SPIIL02-L kit for current local-transfer applications.

    Local network AINFI-NET / Cnet
    Local transferINIIT13
    Local network BINFI-NET / Cnet
    05 / Technical Specifications

    Product identity and documented system position

    ModelINIIT13
    Product typeINFI-to-INFI-Net local transfer module
    System familyBailey INFI 90 / Symphony Harmony rack communications
    Functional positionCommunication between two local control networks
    ABB catalog identityINIIT13R
    Catalog descriptionINIIT13, Infi to Infi-Net Local Transfer
    ABB product typeSpare_Parts
    Installation contextLocal transfer interface with companion network-interface and termination hardware
    Current Symphony Plus transfer moduleSPIIT13
    Current bundled local-transfer kitSPIIL02-L
    02 / Local Transfer Architecture

    Keep the two network sides visible during fault finding

    Because the transfer path joins two networks, a communication symptom may originate on either side of the bridge or in the transfer hardware itself.

    1Identify both network nodesRecord the addresses and interface modules serving network A and network B.
    2Compare network statusDetermine whether one network is healthy locally before investigating the bridge.
    3Capture the full installed assemblyPhotograph the INIIT13, companion cards, termination hardware and cable labels.
    4Preserve configurationSave the transfer and network settings before disturbing a working partner or replacing the module.
    03 / Evolution & Related Hardware

    ABB's current local-transfer platform uses SPIIT13

    The current catalog describes SPIIT13 as the local transfer module and offers the SPIIL02-L bundle for a complete local-transfer interface. This is an evolution reference, not a license to swap a single card without engineering review.

    SPIIL02-L kit content

    • Two SPNIS21 network interface modules
    • Two NKLS01-10 cables and two NTCL01 termination units
    • One SPIIT13, one IEMMU21 mounting unit and one NFTP01 panel
    04 / Replacement Preparation

    Treat the network pair as one engineered interface

    A module-only match is useful for spare identification, but commissioning depends on the companion modules, termination, cabling, addresses and revision context.

    01

    Nameplate match

    Use INIIT13 as the required spare identity and include any suffix or revision visible on the unit.

    02

    Assembly match

    Compare the connected network-interface modules and cable/termination part numbers.

    03

    Planned evolution

    If moving to SPIIT13 or SPIIL02-L, review the full ABB migration design rather than treating it as a direct plug-in exchange.

    06 / Applications & Fault Scenarios

    Why maintenance teams source INIIT13

    01

    One local network is isolated

    Each network operates locally, but messages no longer cross the local-transfer interface.

    02

    Intermittent cross-network data

    Transfer status, companion interfaces, rack connections or configuration produce an unstable bridge.

    03

    Lifecycle spare planning

    A site wants a tested INIIT13 on hand while it plans a later move to the current SPIIT13 platform.

    07 / Official Documentation

    INIIT13 manufacturer documents

    ManufacturerDocumentNumber / VersionOfficial link
    ABBINIIT13R Product DetailsABB Product ID INIIT13RView document
    ABBSymphony Plus Product Catalog2VAA005340, Rev. C View document
    08 / Supply & RFQ

    Inspection, packing and quotation support

    Amikon Service

    InspectionPart identity and agreed test scope
    Export packingAnti-static and impact-protective
    DOA supportPrompt review with photos and evidence
    Warranty & returnsTerms confirmed on the quotation
    09 / FAQ

    INIIT13 questions from buyers and maintenance teams

    What is ABB INIIT13 used for?

    It provides the local-transfer function between two local INFI-NET or Cnet control networks.

    Is ABB INIIT13 a remote modem transfer module?

    No. Its documented role is local network-to-network transfer; remote serial transfer uses a different interface family.

    What current ABB module is related to ABB INIIT13?

    The current Symphony Plus catalog documents SPIIT13 for the local-transfer role and the SPIIL02-L complete kit.

    What is included in the current kit related to ABB INIIT13?

    SPIIL02-L includes SPIIT13, two SPNIS21 modules, two NKLS01-10 cables, two NTCL01 units, one IEMMU21 and one NFTP01.

    Can ABB INIIT13 be replaced by one SPIIT13 card without further checks?

    A migration should be reviewed at interface level because companion modules, termination, mounting, cables and configuration are part of the local-transfer design.

    What should be provided for an ABB INIIT13 RFQ?

    Send part number, quantity, destination, required date and system model, plus photos of the faceplate and the connected local-transfer assembly.

    10 / Multi-brand Spare Parts Also Requested

    Independent procurement references

    These models are separate sourcing references, not substitutes for INIIT13. Compatibility and stock must be confirmed independently.

    210N2272972-01268-6A-IP20311637312863-A01319828-A01332985-C013G3MX2-A4007-ZV13IF722.93IF761.93IF766.93IF771.93IF772.93IF779.9

    No interchangeability, migration or replacement relationship is implied by this list.

    INIIT13 · ABB / Bailey industrial automation spare · Contact Miya Zheng for availability and quotation support.
    Quality ABB INIIT13 INFINET Communication Module for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: AMIKON LIMITED
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Find Similar Products By Category: